Safe Work Method Statements for Insulation Installation in Construction

Insulation

Used by 500+ Australian construction companies

No credit card required • Instant access • 100% compliant in every Australian state

5 sec
Creation Time
100%
Compliant
2,000+
Companies
$3.6K
Fines Avoided

Avoid WHS penalties up to $3.6M—issue compliant SWMS to every crew before work starts.

Insulation installation is a critical building service that enhances energy efficiency, reduces heating and cooling costs, and improves occupant comfort in residential, commercial, and industrial buildings. Insulation installers work with various materials including fibreglass batts, mineral wool, polyester, reflective foil, and ceiling panel systems. Installation occurs predominantly in roof spaces, wall cavities, and underfloor areas, often in confined environments with limited ventilation and extreme temperatures. This category provides SWMS templates covering all common insulation installation activities, addressing the unique hazards of working in confined roof spaces, exposure to irritant fibres, heat stress, and electrical hazards in accordance with Australian WHS legislation and industry standards.

Unlimited drafts • Built-in WHS compliance • Works across every Australian state

Insulation Overview

3 curated templates

Insulation installation is a critical building service that enhances energy efficiency, reduces heating and cooling costs, and improves occupant comfort in residential, commercial, and industrial buildings. Insulation installers work with various materials including fibreglass batts, mineral wool, polyester, reflective foil, and ceiling panel systems. Installation occurs predominantly in roof spaces, wall cavities, and underfloor areas, often in confined environments with limited ventilation and extreme temperatures. This category provides SWMS templates covering all common insulation installation activities, addressing the unique hazards of working in confined roof spaces, exposure to irritant fibres, heat stress, and electrical hazards in accordance with Australian WHS legislation and industry standards.

Definition

What is Insulation?

Insulation installation in the construction industry involves the placement of thermal and acoustic materials within building structures to control heat transfer, reduce sound transmission, and improve energy efficiency. Modern Australian buildings require insulation to meet Building Code of Australia requirements and achieve energy efficiency ratings under the Nationwide House Energy Rating Scheme (NatHERS). Insulation installers work across new construction projects and retrofit applications in existing buildings. Thermal insulation batts represent the most common installation method, involving placement of pre-cut fibreglass, polyester, or mineral wool batts between ceiling joists, wall studs, and floor joists. This work requires installers to access roof spaces, often working in extreme temperatures that can exceed 50 degrees Celsius in summer months. Installers must navigate around structural members, electrical wiring, and ductwork while handling materials that can cause skin irritation and respiratory discomfort. Proper installation technique is essential to avoid compressing batts, which reduces their thermal effectiveness, and to maintain required clearances from heat-producing fixtures and electrical components. Ceiling panel insulation systems offer an alternative approach, particularly in commercial buildings and retrofit applications. These systems involve installing rigid or semi-rigid panels above ceiling tiles or attaching them directly to roof structures. Installation requires working from ladders or scaffolding to position panels accurately while managing weight distribution and ensuring secure fixing. Installers must coordinate with other trades to avoid damaging existing services and ensure compatibility with ceiling systems, ventilation equipment, and lighting installations. Reflective foil insulation, commonly known as sisalation or sarking, provides a radiant barrier that reflects heat rather than absorbing it. Installation typically occurs during initial construction, with installers draping reflective material across roof trusses before roof sheeting installation. This work requires careful attention to installation orientation, maintaining air gaps for reflective effectiveness, and ensuring proper overlap and sealing at joins. Foil insulation work presents unique electrical hazards, as the conductive material can bridge electrical circuits if it contacts wiring or if installers work near overhead power lines during external installation phases.

Compliance impact

Why it matters

Insulation installation presents significant occupational health and safety risks that have resulted in fatalities and serious injuries across Australia. The industry gained national attention following the tragic deaths of four young workers during the Home Insulation Program in 2009-2010, incidents that directly resulted from inadequate safety systems, insufficient training, and failure to identify and control electrical hazards. These fatalities led to regulatory reforms including mandatory licensing for insulation installers in several Australian states and heightened WorkSafe scrutiny of insulation activities. Under the Work Health and Safety Act 2011, persons conducting a business or undertaking (PCBUs) have a primary duty of care to eliminate risks or, where elimination is not reasonably practicable, to minimise risks so far as is reasonably practicable. For insulation installation, this duty extends to comprehensive hazard identification, risk assessment, implementation of control measures, and documentation through task-specific SWMS. Safe Work Australia specifically identifies working in confined spaces, work near energised electrical installations, and work in extreme temperatures as high-risk activities requiring particular attention in safety planning. Australian Standards provide crucial guidance for safe insulation installation practices. AS/NZS 3000 (Electrical Installations) specifies required clearances between insulation materials and electrical equipment, heat-producing fixtures, and recessed lighting. AS/NZS 3999 (Thermal Insulation of Dwellings) details installation requirements ensuring both effectiveness and safety. AS 4200.1 (Pliable Building Membranes and Underlays) covers requirements for reflective foil installation. Compliance with these standards protects workers from electrical hazards, fire risks, and heat stress while ensuring installed insulation performs as intended. The regulatory environment for insulation work varies across Australian states and territories. Victoria, Queensland, South Australia, and the Australian Capital Territory require insulation installers to hold specific licences demonstrating competency in safe work practices, electrical hazard identification, and proper installation techniques. All jurisdictions require the Construction Induction White Card. Electrical safety is paramount—all insulation work must include isolation or protection from electrical hazards, with many jurisdictions requiring licensed electricians to verify safety before insulation installation in roof spaces containing electrical installations. Heat stress represents a persistent hazard in insulation work. Roof space temperatures commonly exceed 50 degrees Celsius in summer, with some areas reaching 70 degrees. Combined with physical exertion, protective clothing, and limited ventilation, these conditions create extreme heat stress risk. Safe Work Australia guidance requires employers to implement heat management controls including work-rest cycles, hydration protocols, acclimatisation programs, and heat stress monitoring. Fatalities have occurred when these controls were absent or inadequately implemented. Having comprehensive, regularly reviewed SWMS demonstrates due diligence, ensures systematic hazard control, facilitates effective worker training, and provides documented evidence of safety planning for regulatory compliance. Given the industry's history and continued regulatory attention, insulation contractors cannot afford inadequate safety documentation.

Key hazards in Insulation

Highlight high-risk scenarios before work begins.

Risk focus
Hazard

Electrocution from Contact with Electrical Wiring

Insulation installers work in close proximity to electrical wiring, junction boxes, light fittings, and other electrical installations within roof spaces and wall cavities. Contact with energised conductors can cause fatal electric shock. Specific risks include touching exposed wiring, damaging cable insulation when moving through confined spaces, installing conductive foil insulation that contacts wiring, and working near recessed light fittings that remain energised. The 2009-2010 fatalities highlighted this hazard when young workers contacted live electrical wiring in roof spaces. Risk is elevated when working in poorly lit spaces, when electrical installations are non-compliant, and when installers lack electrical hazard awareness. Control measures must include pre-installation electrical safety inspections by licensed electricians, isolation of circuits where practicable, use of non-conductive tools, maintaining required clearances from electrical equipment as specified in AS/NZS 3000, provision of adequate lighting, and comprehensive training in electrical hazard recognition.

Hazard

Heat Stress and Heat-Related Illness

Roof space temperatures in Australian summers regularly exceed 50 degrees Celsius and can reach 70 degrees in metal roofed buildings under direct sun exposure. Combined with physical exertion, limited air movement, and required protective clothing, these extreme conditions create severe heat stress risk. Heat-related illnesses progress from heat cramps and heat exhaustion to potentially fatal heat stroke. Symptoms include excessive sweating, weakness, confusion, and loss of consciousness. Risk factors include inadequate acclimatisation, insufficient hydration, extended work periods without rest breaks, and individual health conditions. Older workers and those with cardiovascular conditions face elevated risk. Control measures include scheduling work during cooler morning hours, implementing mandatory work-rest cycles with duration based on temperature monitoring, providing cool rest areas with air-conditioning or fans, ensuring unlimited access to cool drinking water, acclimatisation programs for new workers, heat stress training, buddy systems for monitoring co-workers, and emergency response procedures for heat illness.

Hazard

Falls Through Fragile Roofing and Ceilings

Insulation installers must traverse roof spaces by stepping only on structural ceiling joists, typically spaced 600mm apart. Stepping between joists onto ceiling material causes falls through fragile plasterboard or fibrous cement ceilings, resulting in falls of 2-4 metres to floor level below. These falls frequently cause fractures, spinal injuries, and head trauma. Risk increases in poorly lit roof spaces, when carrying materials that obstruct foot placement visibility, during hot conditions when fatigue impairs concentration, and in older buildings where ceiling materials have deteriorated. Additional hazards exist when working beneath or on fragile roof materials including old fibro-cement sheeting and translucent roof panels. Control measures include installing walkboards or planks across joists to create safe working platforms, ensuring adequate lighting with headlamps or portable work lights, limiting material loads to allow safe movement, providing clear access pathways marked on site plans, pre-work roof space inspections to identify hazards, and when working on roofs, installing roof edge protection and identifying fragile roof areas with warning signs and barriers.

Hazard

Exposure to Fibrous Materials and Airborne Particles

Fibreglass and mineral wool insulation materials release fine fibres and particles when handled, cut, or compressed. These fibres cause skin irritation, eye irritation, and respiratory discomfort. While not classified as carcinogens, fibres can trigger allergic responses and respiratory sensitisation in susceptible individuals. Prolonged skin contact causes persistent itching and dermatitis. Eye contact causes severe irritation and corneal scratching if rubbed. Inhalation causes throat irritation, coughing, and temporary respiratory discomfort. Risk is elevated when working in confined spaces with poor ventilation, during hot conditions when sweating increases skin irritation, and when handling older insulation materials being removed that have accumulated dust and contaminants. Control measures include selecting low-irritant insulation products where available, provision of appropriate PPE including long-sleeved coveralls, gloves rated for fibreglass protection, safety glasses or goggles, and P2 respirators when required, ensuring adequate ventilation in work areas, minimising material cutting and compression, providing washing facilities for removing fibres from skin, and training workers to avoid touching face and eyes with contaminated gloves.

Hazard

Confined Space Hazards

Many roof spaces and underfloor areas where insulation is installed meet the definition of confined spaces under WHS regulations due to limited access, poor ventilation, and presence of atmospheric hazards. Confined space risks include oxygen deficiency, accumulation of toxic gases from building materials, poor air quality from dust and fibres, and difficulty with rescue in medical emergencies. Specific scenarios include roof spaces with limited access points, underfloor areas in older buildings with soil gas ingress, and areas where ventilation openings are blocked or inadequate. Risk increases when using fuel-burning equipment in these spaces, when multiple workers occupy small roof spaces depleting oxygen, and when working in recently treated timber structures that off-gas preservative chemicals. Control measures include assessment of each work location to determine if it meets confined space criteria, implementing confined space entry procedures where required including atmospheric testing, forced ventilation, standby personnel, and emergency retrieval equipment, ensuring adequate natural or mechanical ventilation before and during work, and limiting number of workers in confined roof spaces.

Hazard

Manual Handling Injuries from Carrying Materials

Insulation installers frequently lift, carry, and manoeuvre insulation batts, rolls, and panels through confined roof space access points and along roof joists. While individual batts are relatively light, accumulated handling over work shifts creates fatigue and injury risk. Larger ceiling panel systems are heavier and bulkier, requiring team lifting. Awkward access through roof hatches or eaves access points forces workers to lift materials overhead or twist while passing materials to co-workers. Working in cramped roof spaces requires kneeling, crawling, and working in awkward postures that stress knees, backs, and shoulders. Risk increases when rushing to meet production targets and during hot conditions when fatigue sets in earlier. Control measures include using mechanical aids such as material hoists where practicable, passing materials in smaller quantities rather than bulk loads, team lifting for heavier materials, positioning material storage close to access points to minimise carrying distance, implementing task rotation to vary physical demands, scheduled rest breaks, and training in correct manual handling techniques specific to insulation materials.

Hazard

Inadequate Lighting and Visibility

Roof spaces typically lack permanent lighting, creating poor visibility for identifying hazards, locating electrical wiring, and seeing foot placement on ceiling joists. Inadequate lighting increases risk of trips, falls through ceilings, contact with electrical hazards, and working errors. Natural light entering through roof ventilators or gable vents is insufficient in most cases, particularly when working during overcast conditions or in building sections away from ventilation openings. Working in dim conditions causes eye strain and fatigue. Control measures include provision of adequate portable lighting with LED work lights that generate minimal heat, headlamps for hands-free lighting, ensuring lights are positioned to illuminate work areas and travel paths without creating glare, battery-powered lighting to eliminate electrical cords creating trip hazards, and allowing time for eyes to adjust when entering dark roof spaces from bright outdoor conditions.

Hazard

Biological Hazards Including Rodents and Vermin

Roof spaces and underfloor areas often contain evidence of rodent activity including droppings, nesting materials, and deceased animals. Contact with rodent urine or droppings can transmit diseases including leptospirosis and lymphocytic choriomeningitis. Disturbing old insulation or stored materials may expose workers to accumulated dust containing rodent waste. Additionally, roof spaces may contain wasp or bee nests, spiders including potentially dangerous species, and in some regions, snakes seeking shelter. Bites and stings can cause serious reactions requiring medical treatment. Risk increases in older buildings, rural areas, and buildings that have been vacant. Control measures include pre-work inspection of roof spaces to identify evidence of pest activity, engaging pest control professionals to remove active infestations before insulation work commences, wearing gloves to avoid direct contact with contaminated materials, using respirators when disturbing old insulation, first aid training including management of bites and stings, and having bite and sting treatment supplies readily available.

Benefits of using a Insulation SWMS

  • Demonstrate compliance with state-specific insulation installer licensing requirements and WHS Act obligations, protecting against regulatory penalties
  • Address electrical safety comprehensively, implementing lessons learned from the 2009-2010 fatalities and current best practice
  • Provide systematic heat stress management procedures protecting workers during extreme summer roof space temperatures
  • Create clear documentation for toolbox meetings covering insulation-specific hazards including electrical risks, heat stress, and confined space considerations
  • Facilitate efficient pre-work site assessments identifying electrical hazards, roof space access issues, and environmental conditions
  • Support tender submissions by demonstrating robust safety management systems specific to insulation installation hazards
  • Reduce WorkCover premiums through documented safety systems and lower incident rates
  • Ensure consistent safety standards across different installation crews and project sites

Available SWMS templates

Hand-crafted documents ready to customise for your teams.

View all 3 documents

Frequently asked questions

Do insulation installers need specific licences beyond the Construction White Card?

Licensing requirements for insulation installers vary across Australian states and territories. Victoria requires an Insulation Installer Registration through the Victorian Building Authority for anyone installing thermal insulation in residential buildings. Queensland requires an Insulation Installer Licence issued by the Queensland Building and Construction Commission. South Australia requires registration as an insulation installer. The Australian Capital Territory has similar requirements. New South Wales, Western Australia, Tasmania, and the Northern Territory currently do not require specific insulation installer licences beyond the mandatory Construction Induction White Card required for all construction work. However, all jurisdictions require appropriate training in electrical hazard awareness, heat stress management, and safe work practices specific to insulation installation. Even in states without licensing, many insurance companies and principal contractors require evidence of formal insulation installation training. Employers must verify that installers hold all required licences and registrations for the jurisdiction where work occurs before commencing insulation activities.

When must a licensed electrician be involved in insulation installation work?

Electrical safety is paramount in insulation work. Safe Work Australia guidance and state regulations require electrical safety verification before insulation installation in roof spaces containing electrical installations. Best practice involves engaging a licensed electrician to conduct a pre-installation safety inspection identifying electrical hazards, verifying that electrical installations comply with AS/NZS 3000, confirming adequate clearances exist between insulation and electrical equipment, and where necessary, modifying installations to ensure safety. Some jurisdictions require this inspection to be documented and provided to the insulation installer. Where electrical hazards are identified that cannot be controlled through clearances and work procedures, circuits must be isolated by a licensed electrician before insulation work commences. Electricians must also verify that recessed light fittings are rated for insulation contact or have appropriate spacing. After installation, an electrical safety verification may be required to ensure no damage to electrical systems occurred. While not every insulation job legally requires electrical inspection, it represents best practice risk management given the industry's history of electrical fatalities.

How should heat stress be managed during summer insulation installation?

Heat stress management is critical for insulation work. Safe Work Australia provides specific guidance for working in hot environments. Effective heat stress control combines multiple measures. Schedule roof space work during cooler morning hours, ideally before 11:00 AM when roof space temperatures are lowest. Implement mandatory work-rest cycles based on temperature monitoring—for example, 45 minutes work followed by 15 minutes rest in cool conditions when temperatures exceed 45 degrees. Provide air-conditioned vehicles or shaded rest areas with fans for cool-down periods. Ensure unlimited access to cool drinking water, with workers consuming at least 200ml every 15-20 minutes. Implement acclimatisation programs for new workers, gradually increasing heat exposure over 7-14 days. Train workers to recognise heat stress symptoms in themselves and co-workers. Use buddy systems where workers monitor each other for signs of heat illness. Consider mechanical ventilation in roof spaces using industrial fans where practicable. Provide appropriate lightweight, light-coloured protective clothing that allows sweat evaporation while protecting from insulation fibres. Have emergency procedures for heat illness including immediate cooling measures and medical response. During extreme heat conditions, consider suspending work when safe work-rest cycles become impractical.

What PPE is required for insulation installation and how should it be selected?

Personal protective equipment for insulation work must address multiple hazards. Respiratory protection is required when working in dusty conditions or when disturbing old insulation—disposable P2 rated particulate respirators provide adequate protection for insulation fibres in most conditions. Eye protection is mandatory, with safety glasses providing minimum protection, though goggles offer better protection against fibres entering from sides. Skin protection requires long-sleeved coveralls in light colours to reduce heat absorption, made from closely woven material that resists fibre penetration. Disposable coveralls are practical for preventing fibre transfer to vehicles and homes. Gloves must provide protection from fibres while allowing dexterity—cotton gloves with rubber coating provide good balance. Footwear must have slip-resistant soles for walking on roof joists. Hard hats are required on commercial construction sites and recommended for all roof space work. When working in extreme heat, PPE selection becomes critical—use lightweight, breathable materials that still provide protection. The challenge is balancing protection from insulation fibres against heat stress risk. Some modern insulation products marketed as low-itch may allow reduced skin protection, but this must be verified for the specific product. All PPE should be fitted properly, maintained in good condition, and replaced when damaged. Workers must be trained in correct use including putting on and removing coveralls to avoid fibre contact with clothing underneath.

How can installers safely identify and maintain required clearances from electrical equipment?

AS/NZS 3000 specifies minimum clearances between insulation and electrical equipment to prevent overheating and fire risk. Recessed light fittings require particular attention—those rated for insulation contact can be covered, indicated by an IC rating on the fitting. Non-IC rated fittings require minimum 200mm clearance on all sides with no insulation overhead. Transformers, junction boxes, and other heat-producing equipment require similar clearances. Practical implementation involves several steps. Before installation, conduct thorough roof space inspection using adequate lighting to locate all electrical equipment. Mark clearance zones around equipment using spray paint or marking chalk on joists. Photograph electrical installations showing ratings and configurations. Where IC ratings are unclear, treat fittings as non-IC rated and maintain clearances. For transformers and junction boxes, verify ratings and maintain manufacturer-specified clearances. Use pre-cut insulation or carefully cut batts to fit around electrical equipment rather than compressing material to fit. Document clearances with photos showing compliance. Some projects involve replacing non-IC rated fittings with IC-rated fittings before insulation to eliminate clearance requirements, though this electrical work must be performed by licensed electricians. Never assume electrical installations comply with standards—older buildings often contain non-compliant wiring. When in doubt, consult a licensed electrician before proceeding. Maintaining clearances is not optional—it is a legal requirement protecting against fire risk and ensuring compliance with the Building Code of Australia.

Explore related categories

What is Insulation Installation?

Insulation installation in the construction industry involves the placement of thermal and acoustic materials within building structures to control heat transfer, reduce sound transmission, and improve energy efficiency. Modern Australian buildings require insulation to meet Building Code of Australia requirements and achieve energy efficiency ratings under the Nationwide House Energy Rating Scheme (NatHERS). Insulation installers work across new construction projects and retrofit applications in existing buildings. Thermal insulation batts represent the most common installation method, involving placement of pre-cut fibreglass, polyester, or mineral wool batts between ceiling joists, wall studs, and floor joists. This work requires installers to access roof spaces, often working in extreme temperatures that can exceed 50 degrees Celsius in summer months. Installers must navigate around structural members, electrical wiring, and ductwork while handling materials that can cause skin irritation and respiratory discomfort. Proper installation technique is essential to avoid compressing batts, which reduces their thermal effectiveness, and to maintain required clearances from heat-producing fixtures and electrical components. Ceiling panel insulation systems offer an alternative approach, particularly in commercial buildings and retrofit applications. These systems involve installing rigid or semi-rigid panels above ceiling tiles or attaching them directly to roof structures. Installation requires working from ladders or scaffolding to position panels accurately while managing weight distribution and ensuring secure fixing. Installers must coordinate with other trades to avoid damaging existing services and ensure compatibility with ceiling systems, ventilation equipment, and lighting installations. Reflective foil insulation, commonly known as sisalation or sarking, provides a radiant barrier that reflects heat rather than absorbing it. Installation typically occurs during initial construction, with installers draping reflective material across roof trusses before roof sheeting installation. This work requires careful attention to installation orientation, maintaining air gaps for reflective effectiveness, and ensuring proper overlap and sealing at joins. Foil insulation work presents unique electrical hazards, as the conductive material can bridge electrical circuits if it contacts wiring or if installers work near overhead power lines during external installation phases.

Why Insulation SWMS Matters

Insulation installation presents significant occupational health and safety risks that have resulted in fatalities and serious injuries across Australia. The industry gained national attention following the tragic deaths of four young workers during the Home Insulation Program in 2009-2010, incidents that directly resulted from inadequate safety systems, insufficient training, and failure to identify and control electrical hazards. These fatalities led to regulatory reforms including mandatory licensing for insulation installers in several Australian states and heightened WorkSafe scrutiny of insulation activities. Under the Work Health and Safety Act 2011, persons conducting a business or undertaking (PCBUs) have a primary duty of care to eliminate risks or, where elimination is not reasonably practicable, to minimise risks so far as is reasonably practicable. For insulation installation, this duty extends to comprehensive hazard identification, risk assessment, implementation of control measures, and documentation through task-specific SWMS. Safe Work Australia specifically identifies working in confined spaces, work near energised electrical installations, and work in extreme temperatures as high-risk activities requiring particular attention in safety planning. Australian Standards provide crucial guidance for safe insulation installation practices. AS/NZS 3000 (Electrical Installations) specifies required clearances between insulation materials and electrical equipment, heat-producing fixtures, and recessed lighting. AS/NZS 3999 (Thermal Insulation of Dwellings) details installation requirements ensuring both effectiveness and safety. AS 4200.1 (Pliable Building Membranes and Underlays) covers requirements for reflective foil installation. Compliance with these standards protects workers from electrical hazards, fire risks, and heat stress while ensuring installed insulation performs as intended. The regulatory environment for insulation work varies across Australian states and territories. Victoria, Queensland, South Australia, and the Australian Capital Territory require insulation installers to hold specific licences demonstrating competency in safe work practices, electrical hazard identification, and proper installation techniques. All jurisdictions require the Construction Induction White Card. Electrical safety is paramount—all insulation work must include isolation or protection from electrical hazards, with many jurisdictions requiring licensed electricians to verify safety before insulation installation in roof spaces containing electrical installations. Heat stress represents a persistent hazard in insulation work. Roof space temperatures commonly exceed 50 degrees Celsius in summer, with some areas reaching 70 degrees. Combined with physical exertion, protective clothing, and limited ventilation, these conditions create extreme heat stress risk. Safe Work Australia guidance requires employers to implement heat management controls including work-rest cycles, hydration protocols, acclimatisation programs, and heat stress monitoring. Fatalities have occurred when these controls were absent or inadequately implemented. Having comprehensive, regularly reviewed SWMS demonstrates due diligence, ensures systematic hazard control, facilitates effective worker training, and provides documented evidence of safety planning for regulatory compliance. Given the industry's history and continued regulatory attention, insulation contractors cannot afford inadequate safety documentation.

Trusted by 1,500+ Australian construction teams

Insulation SWMS Sample

Professional insulation SWMS created in 5 seconds with OneClickSWMS

  • Instant PDF & shareable link
  • Auto-filled risk matrix
  • Editable Word download
  • State-specific compliance
  • Digital signature ready
  • Version history preserved
Manual creation2-3 hours
OneClickSWMS5 seconds
Save 99% of admin time and eliminate manual errors.

No credit card required • Instant access • Unlimited drafts included in every plan

PDF Sample

Risk Rating

BeforeHigh
After ControlsLow

Key Controls

  • • Pre-start briefing covering hazards
  • • PPE: hard hats, eye protection, gloves
  • • Emergency plan communicated to crew

Signature Ready

Capture digital signatures onsite and store revisions with automatic timestamps.

Continue exploring

Hand-picked SWMS resources

Ready to deliver professional SWMS in minutes?

OneClickSWMS powers thousands of compliant projects every week. Join them today.