Temporary site power gets moved, driven over and exposed to rain as a build changes. Connecting boards or switching to permanent supply can expose live parts or leave an unexpected source connected. Describe the job and site so the draft reflects your work, then check the SWMS with the crew before starting.

A$39per job

However many high-risk activities it covers.

  • 3 for A$99
  • 10 for A$249
  • Yearly A$129 for 120
  • Monthly A$60 for 10

You review it on site before work starts.

The draft is a starting point. You check every step against the site, your crew and the builder's rules, then finalise.
YB

Your Business

Safe Work Method Statement

Version 1
Draft

Electrical temporary connections

Site Your site address

Law Your state

High-risk construction work

  • Work on or near energised electrical installations

Job steps, hazards and controls

1Plan site supply and cable routesTraffic damage and water exposureHighLocate boards and cables away from site hazards
2Isolate supplies and install boardsLive terminals and alternate feedsHighLock out every source and test for dead
3Run cables and connect outletsCrushed leads and loose connectionsHighProtect crossings and support cables along the planned route
4Test and energise site powerFaults and failed protectionHighComplete electrical tests before controlled energisation
5Change over and remove temporary supplyBack-feed and mistaken circuit identityHighConfirm source isolation before altering or removing connections
Illustrative example

Illustrative first page. Yours carries your business name only.

What you get

What your electrical temporary connections SWMS will contain

An A4 document your crew can read on site, a PDF for the builder and a sign-on register.

  • Job and site detailsYour business, the site, the principal contractor, the dates.
  • High-risk construction workThe categories your job involves, ticked.
  • Step-by-step methodEach step with its hazards, risk rating and controls.
  • How controls are checkedWho puts each control in place, monitors and reviews it.
  • PPE, plant and permitsEquipment and training the job needs.
  • Emergency planAssembly point, first aid, nearest hospital to confirm on site.
  • Consultation and reviewWho was consulted, when it is reviewed.
  • Sign-on registerYour crew signs by QR or on paper.

High-risk construction work

Categories this task often involves

You tick the ones your job involves. Each ticked category gets its own steps and controls, in your state's wording.

  • Work on or near energised electrical installations
All high-risk construction work categories

State notes

Rules depend on your state

Pick your state when you start. Your state's regulator publishes the rules and guidance for this work.

Hazards and controls

What goes wrong on a electrical temporary connections job, and how the SWMS controls it

These rows are written for this task. Your draft adds the ones your site and method need.

  1. 1

    Shock at temporary board terminals during supply connection

    High
    • Isolate, lock and tag incoming and alternate supplies before connection
    • Prove the tester, test for dead and recheck the tester afterwards
  2. 2

    Temporary power cables crushed by construction traffic

    High
    • Route cables outside plant paths and protect unavoidable crossings
    • Inspect cable supports and remove damaged leads from use
  3. 3

    Rain entering temporary distribution boards and sockets

    High
    • Use enclosures and connections suited to the work location
    • Position boards clear of water collection and inspect after wet weather
  4. 4

    Temporary circuits overheating as extra site loads are added

    High
    • Plan circuit loading and provide suitable distribution for connected equipment
    • Check added loads and remove damaged or overheating connections from service
  5. 5

    Generator back-feed during temporary to permanent changeover

    High
    • Identify and isolate generator, temporary and permanent sources before switching
    • Use a documented changeover sequence and verify dead before altering connections
  6. 6

    Failed protective devices on temporary site outlets

    High
    • Test protective devices before putting the temporary installation into service
    • Isolate defective circuits and record checks after changes to the installation

How the job usually runs

  1. 1Plan site supply and cable routesTraffic damage and water exposure → Locate boards and cables away from site hazards
  2. 2Isolate supplies and install boardsLive terminals and alternate feeds → Lock out every source and test for dead
  3. 3Run cables and connect outletsCrushed leads and loose connections → Protect crossings and support cables along the planned route
  4. 4Test and energise site powerFaults and failed protection → Complete electrical tests before controlled energisation
  5. 5Change over and remove temporary supplyBack-feed and mistaken circuit identity → Confirm source isolation before altering or removing connections

PPE for this job

  • Arc-rated clothing suited to switching
  • Arc-rated face shield
  • Insulated gloves suited to the work
  • Safety glasses
  • Safety boots
  • Safety helmet

Your draft lists the PPE your site and method need.

After you finalise

Brief your crew and send it to your builder

Crew signs by QR

Pass your phone around or print the A4 sign-on sheet. Workers read and sign on their own phones, no account.

Send to my builder

One tap emails the PDF and the version to your builder, or upload it to their inbox link.

PDF and register

A clean A4 PDF with your business name, and a register of who signed which version.

Builder sent it back?

Make their changes and re-issue the same job free. Workers re-sign the new version.

What builders check

Questions

Electrical temporary connections SWMS questions

Last reviewed
21 October 2026
How
Hazard rows checked against the task; no legal line is stated unless it is logged from primary text.
Next review
Every six months, or when the method or rules change
Does it cover changing from generator to permanent power?

Yes. Describe every supply and the changeover arrangement. The draft covers source identification, isolation, testing and the order for disconnecting temporary equipment before permanent supply is used.

What if the builder wants to move a temporary board?

The draft covers reassessing cable routes, site loads and weather exposure, then isolating, reconnecting and testing the installation before the board returns to service at its new position.

How much does a electrical temporary connections SWMS cost?

One job uses 1 SWMS when you finalise: A$39 for one, however many high-risk activities it covers. AI drafting needs a SWMS pack or plan. Packs and Yearly cost less per SWMS.

Is this a template?

No. You describe the job and the site, and the SWMS is drafted for them. You edit anything, then finalise it.

Who checks the SWMS?

You do, with your crew, on site before work starts. The draft gives you a strong starting point; the person running the work makes sure it matches the site.

My builder sent it back. What now?

Open it, make the changes they asked for and re-issue it. Corrections to the same job are free.

How does my crew sign it?

Show the QR code on your phone or print the A4 sign-on sheet. Workers read and sign on their own phones without an account.

Does it work in my state?

Yes. You choose the state before drafting, and the document names the law that applies there. Victoria uses its OHS Regulations.

A$39 a job · you review it on site
Start my SWMS